Your Cart

Free Shipping on Orders > $99.99 - *Some Exclusions May Apply

expand/collapse
(704) 979-7100 (0)
  • Big Dog 1000VA Online UPS 8-Outlets Pure Sine Wave - 2U
  • Big Dog 1000VA Online UPS 8-Outlets Pure Sine Wave - 2U
  • Big Dog 1000VA Online UPS 8-Outlets Pure Sine Wave - 2U
  • Big Dog 1000VA Online UPS 8-Outlets Pure Sine Wave - 2U
  • Big Dog 1000VA Online UPS 8-Outlets Pure Sine Wave - 2U
  • Big Dog 1000VA Online UPS 8-Outlets Pure Sine Wave - 2U
  • Big Dog 1000VA Online UPS 8-Outlets Pure Sine Wave - 2U
  • Big Dog 1000VA Online UPS 8-Outlets Pure Sine Wave - 2U
  • Big Dog 1000VA Online UPS 8-Outlets Pure Sine Wave - 2U
  • Big Dog 1000VA Online UPS 8-Outlets Pure Sine Wave - 2U

Big Dog 1000VA Online UPS 8-Outlets Pure Sine Wave - 2U

SKU#: PR-R8U1K

UPC#:

60 Day Money Back Guarantee

100% Secure Shopping

SKU#: PR-R8U1K

UPC#:
$1,849.99

SKU#: PR-R8U1K

UPC#:

Same Day Shipping likely on orders placed in the next 00 hours 00 minutes 00 seconds.

Califonia Warning 65

California Prop 65 Warning

×
For CA Residents Only.
California Proposition 65 Warning

Proposition 65, officially the Safe Drinking Water and Toxic Enforcement Act of 1986, is a law that requires warnings be provided to California consumers when they might be exposed to chemicals identified by California as causing cancer or reproductive toxicity. The warnings are intended to help California consumers make informed decisions about their exposures to these chemicals from the products they use. The California Office of Environmental Health Hazard Assessment (OEHHA) administers the Proposition 65 program and publishes the listed chemicals, which includes more that 850 chemicals. In August 2016, OEHHA adopted new regulations, effective on August 30, 2018, which change the information required in Proposition 65 warnings.

• WARNING: Some cable, plastic, and metal products may contain chemicals known to the state of CA to cause cancer, birth defects, or other reproductive harm.

For further information, please visit www.P65Warnings.ca.gov

  • Description+
  • 1000VA Online UPS 8-Outlets Pure Sine Wave

    The PR-R8U1K is a UPS that integrates with the Big Dog Power: Power Distribution system (PR-R13PI and PR-V7PI) to give a seamless experience when you have equipment that needs to stay running for as long as possible in the event of a power outage. This is a 2U rack mounted 1000VA Online UPS with 8 Total outlets, with 4 always on and a group of 4 programmable outlets. Due to the Online nature of this PDU, there is no relay to switch power from the AC mains to the battery power which means no period where there may not be power, saving those sensitive electronics from short term power loss errors.

  • Features+
    • 2RU rack mountable
    • Uninterruptable Power Supply
    • Online UPS Power
    • 1000VA/1000W Capacity
    • Two 12-volt 9 Amp Hour batteries
    • Input Rating: 110-127VAC @ 50/G0Hz 15A
    • 1000W Output Rating at 120VAC input
    • Load Shedding when paired with Big Dog PDU (PR-R13PI, PR-V7PI)
    • Configurable Voltage and Frequency output
  • Specs+
  • CAPACITY: 1000VA/1000W

    INPUT

    VOLTAGE RANGE: Low Line Transfer - 80VAC/70VAC/60VAC/55VAC ± 5 % ( based on load percentage 100% -80 % / 80 % -70 % / 70 -60 % / 60 % -0)

    Low Line Comeback 87VAC/77VAC/67VAC/62VAC ± 5 %

    High Line Transfer 150 VAC ± 5 % ; High Line Comeback -145 VAC ± 5 % 

    FREQUENCY RANGE: 40Hz - 70 Hz

    PHASE: Single Phase with Ground

    POWER FACTOR: ≥0.99 @full load ≤5%@205-245VAC or 100-130VAC 

    THDU: < 1.6%@ input and full linear load condition

    OUTPUT

    OUTPUT VOLTAGE: 100/110/115/120/127 VAC

    AC VOLTAGE REGULATION: ±1% (Batt. Mode)

    FREQUENCY RANGE (SYNCHRONIZED RANGE): 47 - 53 Hz or 57 - 63 Hz FREQUENCY RANGE: 60Hz ±0.1 Hz (Batt. Mode)

    CURRENT CREST RATIO: 3:1

    HARMONIC DISTORTION: ≤2 % THD (Linear Load) ; 4 % THD (Non-linear Load) ; Zero; < 4 ms 

    WAVEFORM (BATT. MODE): Pure Sinewave

    EFFICIENCY

    AC MODE: ≥91%@ full charged battery

    ECO MODE: ≤96%@ full charged battery

    BATTERY MODE: ≥90%

    BATTERY

    BATTERY TYPE: 12V/9AH ; NUMBERS: 2

    RECHARGE TIME: 3 hours recover to 95% capacity for internal battery@ 2A charging current 

    CHARGING CURRENT: 100/110/115/120 /127 VAC models: default 2A 

    CHARGING VOLTAGE: 27.6 VDC

    PHYSICAL

    DIMENSION, D X W X H (MM): 397 x 220 x 145

    NET WEIGHT (KGS):

    With battery 11.7

    Without battery 6.7

    ENVIRONMENT

    OPERATION HUMIDITY: 20-95 % RH @ 0-40°( (non-condensing)

    NOISE LEVEL: Less than 50dBA @ 1 Meter (With fan speed control)

  • Reviews+
  • 1000VA Online UPS 8-Outlets Pure Sine Wave

    The PR-R8U1K is a UPS that integrates with the Big Dog Power: Power Distribution system (PR-R13PI and PR-V7PI) to give a seamless experience when you have equipment that needs to stay running for as long as possible in the event of a power outage. This is a 2U rack mounted 1000VA Online UPS with 8 Total outlets, with 4 always on and a group of 4 programmable outlets. Due to the Online nature of this PDU, there is no relay to switch power from the AC mains to the battery power which means no period where there may not be power, saving those sensitive electronics from short term power loss errors.

    • 2RU rack mountable
    • Uninterruptable Power Supply
    • Online UPS Power
    • 1000VA/1000W Capacity
    • Two 12-volt 9 Amp Hour batteries
    • Input Rating: 110-127VAC @ 50/G0Hz 15A
    • 1000W Output Rating at 120VAC input
    • Load Shedding when paired with Big Dog PDU (PR-R13PI, PR-V7PI)
    • Configurable Voltage and Frequency output

    CAPACITY: 1000VA/1000W

    INPUT

    VOLTAGE RANGE: Low Line Transfer - 80VAC/70VAC/60VAC/55VAC ± 5 % ( based on load percentage 100% -80 % / 80 % -70 % / 70 -60 % / 60 % -0)

    Low Line Comeback 87VAC/77VAC/67VAC/62VAC ± 5 %

    High Line Transfer 150 VAC ± 5 % ; High Line Comeback -145 VAC ± 5 % 

    FREQUENCY RANGE: 40Hz - 70 Hz

    PHASE: Single Phase with Ground

    POWER FACTOR: ≥0.99 @full load ≤5%@205-245VAC or 100-130VAC 

    THDU: < 1.6%@ input and full linear load condition

    OUTPUT

    OUTPUT VOLTAGE: 100/110/115/120/127 VAC

    AC VOLTAGE REGULATION: ±1% (Batt. Mode)

    FREQUENCY RANGE (SYNCHRONIZED RANGE): 47 - 53 Hz or 57 - 63 Hz FREQUENCY RANGE: 60Hz ±0.1 Hz (Batt. Mode)

    CURRENT CREST RATIO: 3:1

    HARMONIC DISTORTION: ≤2 % THD (Linear Load) ; 4 % THD (Non-linear Load) ; Zero; < 4 ms 

    WAVEFORM (BATT. MODE): Pure Sinewave

    EFFICIENCY

    AC MODE: ≥91%@ full charged battery

    ECO MODE: ≤96%@ full charged battery

    BATTERY MODE: ≥90%

    BATTERY

    BATTERY TYPE: 12V/9AH ; NUMBERS: 2

    RECHARGE TIME: 3 hours recover to 95% capacity for internal battery@ 2A charging current 

    CHARGING CURRENT: 100/110/115/120 /127 VAC models: default 2A 

    CHARGING VOLTAGE: 27.6 VDC

    PHYSICAL

    DIMENSION, D X W X H (MM): 397 x 220 x 145

    NET WEIGHT (KGS):

    With battery 11.7

    Without battery 6.7

    ENVIRONMENT

    OPERATION HUMIDITY: 20-95 % RH @ 0-40°( (non-condensing)

    NOISE LEVEL: Less than 50dBA @ 1 Meter (With fan speed control)

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
Open Google Reviews for our website ×