Your Cart

Free Shipping on Orders > $74.99 - *Some Exclusions May Apply

expand/collapse
(704) 979-7100 (0)
  • Anti Static Heel Grounder
  • Anti Static Heel Grounder

Anti Static Heel Grounder

SKU#: HEEL-GROUND

UPC#: 686162558728

60 Day Money Back Guarantee

100% Secure Shopping

SKU#: HEEL-GROUND

UPC#:686162558728
$8.59

SKU#: HEEL-GROUND

UPC#:686162558728

Same Day Shipping likely on orders placed in the next 00 hours 00 minutes 00 seconds.

Califonia Warning 65

California Prop 65 Warning

×
For CA Residents Only.
California Proposition 65 Warning

Proposition 65, officially the Safe Drinking Water and Toxic Enforcement Act of 1986, is a law that requires warnings be provided to California consumers when they might be exposed to chemicals identified by California as causing cancer or reproductive toxicity. The warnings are intended to help California consumers make informed decisions about their exposures to these chemicals from the products they use. The California Office of Environmental Health Hazard Assessment (OEHHA) administers the Proposition 65 program and publishes the listed chemicals, which includes more that 850 chemicals. In August 2016, OEHHA adopted new regulations, effective on August 30, 2018, which change the information required in Proposition 65 warnings.

• WARNING: Some cable, plastic, and metal products may contain chemicals known to the state of CA to cause cancer, birth defects, or other reproductive harm.

For further information, please visit www.P65Warnings.ca.gov

  • Description+
  • Foot grounders provides a continuous ground path between the operator and a properly grounded ESD protected flooring. Foot grounders are designed for use in applications where user mobility is required, such as wave solder, kitting, and quality control. Foot grounders quickly and effectively drain the static charges which collect on personnel during normal, everyday activities. 

    General Guidelines:
    1. Two foot grounders are recommended for reliable grounding and ESD protection, providing ground when one foot is off the floor.
    2. The grounding tab should be tucked inside the shoe with as much contact area as possible to the bottom of the stockinged foot. Foot grounders rely upon the perspiration layer inside of the shoe to make contact through the stocking.
    3. Operator is grounded when foot is in contact with grounded dissipative or conductive flooring.
    4. For most applications, a current limiting resistor in series with the grounding tab is recommended.
    5. It is not recommended to use foot grounders where exposure to line voltages above250V AC is possible.

  • Features+
    • Adjustable with NON-elastic Velcro, Hook and Loop, 3/4" width, Black
    • 0.070'' thick, 1.5'' with, three layer laminated, rubber sole. White Color inner layer is insulative styrene-butadienne-rubber. Outer black colored layer is conductive styrene-butadienne rubber.
    • Sole Exterior: <105 ohms
    • Sole Interior: Non-Marking
    • Burgundy, grounding polyester ribbon tab, 18''/30'' long with 8 conductive nylon strands, two-sided reversible, may be positioned on either side of foot.
    • A 1/4 watt, 1 megohm, 1.5megohm or 2megohm resistor are possible
    • No Silicone is used in the materials that make our foot grounders
  • Reviews+
  • Foot grounders provides a continuous ground path between the operator and a properly grounded ESD protected flooring. Foot grounders are designed for use in applications where user mobility is required, such as wave solder, kitting, and quality control. Foot grounders quickly and effectively drain the static charges which collect on personnel during normal, everyday activities. 

    General Guidelines:
    1. Two foot grounders are recommended for reliable grounding and ESD protection, providing ground when one foot is off the floor.
    2. The grounding tab should be tucked inside the shoe with as much contact area as possible to the bottom of the stockinged foot. Foot grounders rely upon the perspiration layer inside of the shoe to make contact through the stocking.
    3. Operator is grounded when foot is in contact with grounded dissipative or conductive flooring.
    4. For most applications, a current limiting resistor in series with the grounding tab is recommended.
    5. It is not recommended to use foot grounders where exposure to line voltages above250V AC is possible.

    • Adjustable with NON-elastic Velcro, Hook and Loop, 3/4" width, Black
    • 0.070'' thick, 1.5'' with, three layer laminated, rubber sole. White Color inner layer is insulative styrene-butadienne-rubber. Outer black colored layer is conductive styrene-butadienne rubber.
    • Sole Exterior: <105 ohms
    • Sole Interior: Non-Marking
    • Burgundy, grounding polyester ribbon tab, 18''/30'' long with 8 conductive nylon strands, two-sided reversible, may be positioned on either side of foot.
    • A 1/4 watt, 1 megohm, 1.5megohm or 2megohm resistor are possible
    • No Silicone is used in the materials that make our foot grounders