Big Dog 2000VA Online UPS, 8-Outlets, Pure Sine Wave - 2U
Same Day Shipping likely on orders placed in the next 00 hours 00 minutes 00 seconds.
California Prop 65 Warning
For CA Residents Only.
California Proposition 65 Warning
Proposition 65, officially the Safe Drinking Water and Toxic Enforcement Act of 1986, is a law that requires warnings be provided to California consumers when they might be exposed to chemicals identified by California as causing cancer or reproductive toxicity. The warnings are intended to help California consumers make informed decisions about their exposures to these chemicals from the products they use. The California Office of Environmental Health Hazard Assessment (OEHHA) administers the Proposition 65 program and publishes the listed chemicals, which includes more that 850 chemicals. In August 2016, OEHHA adopted new regulations, effective on August 30, 2018, which change the information required in Proposition 65 warnings.
• WARNING: Some cable, plastic, and metal products may contain chemicals known to the state of CA to cause cancer, birth defects, or other reproductive harm.
For further information, please visit www.P65Warnings.ca.gov
- Description+
- Features+
- 2RU rack mountable
- Uninterruptable Power Supply
- Online UPS Power
- 2000V A/2000W Capacity
- Four 12-volt 9 Amp Hour batteries
- Input Rating: 110-127VAC @ 50/G0Hz 16A
- 1850W Output Rating at 120VAC input
- Load Shedding when paired with Big Dog PDU (PR-R13PI, PR-V7PI)
- Configurable Voltage and Frequency output
- Optional NEMA 5-20R To NEMA 5-15P Adapter For 20Amp To 15Amp Plug cable available: PR-PC1520
- Specs+
- CAPACITY*: 2000VA/2000W
- VOLTAGE RANGE: Low Line Transfer - 80VAC/70VAC/60VAC/55VAC 3 5 %
- ( based on load percentage 100% -80 % / 80 % -70 % / 70 -60 % / 60 % -0) Low Line Comback - 87VAC/77VAC/67VAC/62VAC 3 5 %
- High Line Transfer -150 VAC 3 5 % ; High Line Comeback -145 VAC 3 5 % FREQUENCY RANGE: 40Hz - 70 Hz
- PHASE: Single Phase with Ground
- POWER FACTOR: 181 0.99 @full load 181 5%@205-245VAC or 100-130VAC THDU: < 1.6%@ input and full linear load condition
- OUTPUT VOLTAGE: 100/110/115/120/127 VAC
- AC VOLTAGE REGULATION: 31% (Batt. Mode)
- FREQUENCY RANGE (SYNCHRONIZED RANGE): 47 - 53 Hz or 57 - 63 Hz FREQUENCY RANGE: 60Hz 3 0.1 Hz (Batt. Mode)
- CURRENT CREST RATIO: 3:1
- HARMONIC DISTORTION: Transfer Time; AC Mode to Battery Mode; Inverter to Bypass
- 1812 % THD (Linear Load) ; 4 % THD (Non-linear Load) ; Zero; < 4 ms WAVEFORM (BATT. MODE): Pure Sinewave
- AC MODE: 18191%@ full charged battery; ECO MODE: 18196%@ full charged battery BATTERY MODE: 18190%
- BATTERY TYPE: 12V/9AH ; NUMBERS: 4
- RECHARGE TIME: 3 hours recover to 95% capacity for internal battery@ 2A charging current CHARGING CURRENT: 100/110/115/120 /127 VAC models: default 2A, max. BA adjustable CHARGING VOLTAGE: 54.7 VDC 31%
- DIMENSION, D X W X H (MM): 510 x 438 x 88
- NET WEIGHT (KGS): With battery -19.5; Without battery -9.4
- OPERATION HUMIDITY: 20-95 % RH @ 0-40°( (non-condensing)
- NOISE LEVEL: Less than 50dBA @ 1 Meter (With fan speed control)
- Reviews+
- 2RU rack mountable
- Uninterruptable Power Supply
- Online UPS Power
- 2000V A/2000W Capacity
- Four 12-volt 9 Amp Hour batteries
- Input Rating: 110-127VAC @ 50/G0Hz 16A
- 1850W Output Rating at 120VAC input
- Load Shedding when paired with Big Dog PDU (PR-R13PI, PR-V7PI)
- Configurable Voltage and Frequency output
- Optional NEMA 5-20R To NEMA 5-15P Adapter For 20Amp To 15Amp Plug cable available: PR-PC1520
- CAPACITY*: 2000VA/2000W
- VOLTAGE RANGE: Low Line Transfer - 80VAC/70VAC/60VAC/55VAC 3 5 %
- ( based on load percentage 100% -80 % / 80 % -70 % / 70 -60 % / 60 % -0) Low Line Comback - 87VAC/77VAC/67VAC/62VAC 3 5 %
- High Line Transfer -150 VAC 3 5 % ; High Line Comeback -145 VAC 3 5 % FREQUENCY RANGE: 40Hz - 70 Hz
- PHASE: Single Phase with Ground
- POWER FACTOR: 181 0.99 @full load 181 5%@205-245VAC or 100-130VAC THDU: < 1.6%@ input and full linear load condition
- OUTPUT VOLTAGE: 100/110/115/120/127 VAC
- AC VOLTAGE REGULATION: 31% (Batt. Mode)
- FREQUENCY RANGE (SYNCHRONIZED RANGE): 47 - 53 Hz or 57 - 63 Hz FREQUENCY RANGE: 60Hz 3 0.1 Hz (Batt. Mode)
- CURRENT CREST RATIO: 3:1
- HARMONIC DISTORTION: Transfer Time; AC Mode to Battery Mode; Inverter to Bypass
- 1812 % THD (Linear Load) ; 4 % THD (Non-linear Load) ; Zero; < 4 ms WAVEFORM (BATT. MODE): Pure Sinewave
- AC MODE: 18191%@ full charged battery; ECO MODE: 18196%@ full charged battery BATTERY MODE: 18190%
- BATTERY TYPE: 12V/9AH ; NUMBERS: 4
- RECHARGE TIME: 3 hours recover to 95% capacity for internal battery@ 2A charging current CHARGING CURRENT: 100/110/115/120 /127 VAC models: default 2A, max. BA adjustable CHARGING VOLTAGE: 54.7 VDC 31%
- DIMENSION, D X W X H (MM): 510 x 438 x 88
- NET WEIGHT (KGS): With battery -19.5; Without battery -9.4
- OPERATION HUMIDITY: 20-95 % RH @ 0-40°( (non-condensing)
- NOISE LEVEL: Less than 50dBA @ 1 Meter (With fan speed control)
2000VA Online UPS, 8-Outlets, Pure Sine Wave
The PR-R8U2K is the first UPS that integrates with the Big Dog Power: Power Distribution system (PR-R13PI and PR-V7PI) to give a seamless experience when you have equipment that needs to stay running for as long as possible in the event of a power outage. This is a 2U rack mounted 2000V A Online UPS with 8 Total outlets and 4 battery powered outlets. Due to the Online nature of this PDU, there is no relay to switch power from the AC mains to the battery power which means no period where there may not be power, saving those sensitive electronics from short term power loss errors. Pure Sinewave
INPUT
OUTPUT
EFFICIENCY
BATTERY
PHYSICAL
ENVIRONMENT
2000VA Online UPS, 8-Outlets, Pure Sine Wave
The PR-R8U2K is the first UPS that integrates with the Big Dog Power: Power Distribution system (PR-R13PI and PR-V7PI) to give a seamless experience when you have equipment that needs to stay running for as long as possible in the event of a power outage. This is a 2U rack mounted 2000V A Online UPS with 8 Total outlets and 4 battery powered outlets. Due to the Online nature of this PDU, there is no relay to switch power from the AC mains to the battery power which means no period where there may not be power, saving those sensitive electronics from short term power loss errors. Pure Sinewave
INPUT
OUTPUT
EFFICIENCY
BATTERY
PHYSICAL
ENVIRONMENT