Your Cart

Free Shipping on Orders > $49.99 - *Some Exclusions May Apply - Use Code YEAR16 for 16% OFF

expand/collapse (704) 979-7100 (0)

Powercom SMK-2000A, 2000VA, 6+0 Outlets

SKU#: SMK-2000A

UPC#:683828992582

60 Day Money Back Guarantee

100% Secure Shopping

SKU#: SMK-2000A

UPC#:683828992582
$566.85

SKU#: SMK-2000A

UPC#:683828992582

SKU#: SMK-2000A

UPC#:683828992582

60 Day Money Back Guarantee

100% Secure Shopping

Same Day Shipping on orders placed in the next 00 hours 00 minutes 00 seconds.

Description+

Powercom SMK-2000A, 2000VA, 6+0 Outlets

Specs+

AC INPUT

  • AC Input Capacity on Battery : 2000VA
  • AC Input Voltage (+/-) : 25% at line input
  • AC Input Frequency : 50 or 60 Hz+/-5% (auto sensing)

AC OUTPUT

  • AC Output Voltage : Pure sine wave at +/-5% of nominal, -10% of nominal after low battery warning
  • AC Output Frequency : 50 or 60 Hz +/- 0.5%
  • AC Output Voltage Regulation : AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal. AVR decrease output voltage 15% below input
  • voltage if +9% to +25% of nominal

PROTECTION

  • Protection Spike : 320 Joules, 2ms
  • Protection EMI/RFI : 10dB at 0.15 MHz, 50 dB at 30 MHz
  • Protection Overload : UPS automatic shutdown if overload exceeds 110% nominal at 20 sec and 125% at 5 sec
  • Protection Transfer Time : 2/4 milliseconds (typical), including detection time
  • Protection Short Protection : UPS output cut off immediately or input fuse( or breaker) protection

BATTERY

  • Battery Type : Hot swappable, sealed, maintenance-free lead acid, with 3 - 6 year lifetime
  • Battery Typical : 4 hours (to 90% of full capacity)
  • Battery Protection : Automatic self-test & discharge protection, replace battery indicator
  • Battery Run Time : ~ 120 minutes

PHYSICAL

  • Weight : 30Kg (66lbs)
  • Dimension : 170x450x226mm (6.7x17.7x8.9")

INDICATOR

  • LCD Indicators Status Indicate line, bypass, inv, backup, fault, bat capacity, load capacity, I/P frequency, O/P voltage, O/P frequency, inside temperature, fault status, load

ALARM

  • Alarm Battery Backup : Slow beeping sound (about 0.25 Hz)
  • Alarm Battery Low : Rapid beeping sound (about 1.00Hz)
  • Alarm Overload : Continue beeping sound

INTERFACE

  • Interface Dry Contact : Sends AC fail and battery low signals, and receives shutdown signal from computer
  • Interface RS-232 : Detect battery low, Schedule UPS on/off, AC input/output power status display
  • Interface Option : Novell, SNMP, Windows NT, Window 95/98/2000/ME/XP/7/8

ENVIRONMENT

  • Environment Ambient : 3,500 meters max. elevation, 0-95% humidity non-condensing, 0-48 deg c
  • Environment Audible <40dBA (1 meter from surface) Environment Storage Condition : 15,000 meters max. elevation

Reviews+

Powercom SMK-2000A, 2000VA, 6+0 Outlets

AC INPUT

  • AC Input Capacity on Battery : 2000VA
  • AC Input Voltage (+/-) : 25% at line input
  • AC Input Frequency : 50 or 60 Hz+/-5% (auto sensing)

AC OUTPUT

  • AC Output Voltage : Pure sine wave at +/-5% of nominal, -10% of nominal after low battery warning
  • AC Output Frequency : 50 or 60 Hz +/- 0.5%
  • AC Output Voltage Regulation : AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal. AVR decrease output voltage 15% below input
  • voltage if +9% to +25% of nominal

PROTECTION

  • Protection Spike : 320 Joules, 2ms
  • Protection EMI/RFI : 10dB at 0.15 MHz, 50 dB at 30 MHz
  • Protection Overload : UPS automatic shutdown if overload exceeds 110% nominal at 20 sec and 125% at 5 sec
  • Protection Transfer Time : 2/4 milliseconds (typical), including detection time
  • Protection Short Protection : UPS output cut off immediately or input fuse( or breaker) protection

BATTERY

  • Battery Type : Hot swappable, sealed, maintenance-free lead acid, with 3 - 6 year lifetime
  • Battery Typical : 4 hours (to 90% of full capacity)
  • Battery Protection : Automatic self-test & discharge protection, replace battery indicator
  • Battery Run Time : ~ 120 minutes

PHYSICAL

  • Weight : 30Kg (66lbs)
  • Dimension : 170x450x226mm (6.7x17.7x8.9")

INDICATOR

  • LCD Indicators Status Indicate line, bypass, inv, backup, fault, bat capacity, load capacity, I/P frequency, O/P voltage, O/P frequency, inside temperature, fault status, load

ALARM

  • Alarm Battery Backup : Slow beeping sound (about 0.25 Hz)
  • Alarm Battery Low : Rapid beeping sound (about 1.00Hz)
  • Alarm Overload : Continue beeping sound

INTERFACE

  • Interface Dry Contact : Sends AC fail and battery low signals, and receives shutdown signal from computer
  • Interface RS-232 : Detect battery low, Schedule UPS on/off, AC input/output power status display
  • Interface Option : Novell, SNMP, Windows NT, Window 95/98/2000/ME/XP/7/8

ENVIRONMENT

  • Environment Ambient : 3,500 meters max. elevation, 0-95% humidity non-condensing, 0-48 deg c
  • Environment Audible <40dBA (1 meter from surface) Environment Storage Condition : 15,000 meters max. elevation