Your Cart

Free Shipping on Orders > $74.99 - *Some Exclusions May Apply

expand/collapse
(704) 979-7100 (0)
  • Powercom KIN-2200APRM, 3U Rackmount 6 Outlet 2200VA/1320W
  • Powercom KIN-2200APRM, 3U Rackmount 6 Outlet 2200VA/1320W

Powercom KIN-2200APRM, 3U Rackmount 6 Outlet 2200VA/1320W

SKU#: KIN-2200APRM

UPC#: 683828992575

60 Day Money Back Guarantee

100% Secure Shopping

SKU#: KIN-2200APRM

UPC#:683828992575
$407.99

SKU#: KIN-2200APRM

UPC#:683828992575

Same Day Shipping likely on orders placed in the next 00 hours 00 minutes 00 seconds.

Califonia Warning 65

California Prop 65 Warning

×
For CA Residents Only.
California Proposition 65 Warning

Proposition 65, officially the Safe Drinking Water and Toxic Enforcement Act of 1986, is a law that requires warnings be provided to California consumers when they might be exposed to chemicals identified by California as causing cancer or reproductive toxicity. The warnings are intended to help California consumers make informed decisions about their exposures to these chemicals from the products they use. The California Office of Environmental Health Hazard Assessment (OEHHA) administers the Proposition 65 program and publishes the listed chemicals, which includes more that 850 chemicals. In August 2016, OEHHA adopted new regulations, effective on August 30, 2018, which change the information required in Proposition 65 warnings.

• WARNING: Some cable, plastic, and metal products may contain chemicals known to the state of CA to cause cancer, birth defects, or other reproductive harm.

For further information, please visit www.P65Warnings.ca.gov

  • Description+
  • Powercom KIN-2200APRM, 3U Rackmount 6 Outlet 2200VA/1320W

    Note: This product has been discontinued.

  • Specs+
  • AC INPUT

    • AC Input Capacity on Battery : 2200VA
    • AC Input Voltage (+/-) 25% at line input
    • AC Input Frequency : 50 or 60 Hz+/-10% (auto sensing)

    AC OUTPUT

    • AC Output Voltage Simulated sine ware at 115V +/-5%
    • AC Output Frequency : 50 or 60 Hz +/- 0.5%
    • AC Output Voltage Regulation AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal. AVR decrease output voltage 13% below input
    • voltage if +9% to +25% of nominal
    • AC Output Transfer : 2/4 milliseconds, including detection time

    PROTECTION

    • Protection Spike : 320 Joules, 2ms
    • Protection EMI/RFI : 10dB at 0.15 MHz, 50 dB at 30 MHz
    • Protection Overload UPS automatic shutdown if overload exceeds 110% nominal at 60 sec and 130% at 3 sec
    • Protection Unit Fuse for overload & short circuit protection
    • Protection 10 BaseT Network (UTP, RJ-45) compatible jacks
    • Protection Short Protection UPS output cut off immediately or input fuse protection

    BATTERY

    • Battery Type : Sealed, Maintenance-free lead acid
    • Battery Typical 8 hours (to 90% of full capacity)
    • Battery Protection Automatic self-test & discharge protection, replace battery indicator

    BACKUP TIME

    • Battery Backup Time Full Load : 7 minutes
    • Battery Backup Time Half Load : 15 minutes

    PHYSICAL

    • Physical Weight : 28Kg (61.1lbs)
    • Physical Shipping Weight kgs 32.7Kg (72lbs)
    • Physical Dimension : 483x351x130mm (19x13.8x5.1")

    ALARM

    • Alarm Battery Backup : Slow beeping sound (about 0.47 Hz)
    • Alarm Battery Low : Rapid beeping sound (about 1.82Hz)
    • Alarm Overload : Continue beeping sound

    INTERFACE

    • Interface RS-232 : RS-232C Bi-directional communication port

    ENVIRONMENT

    • Environment Ambient : 3,500 meters max. elevation, 0-95% humidity non-condensing, 0-40 deg c
    • Environment Audible : <40dBA (1 meter from surface) Environment Storage Condition : 15,000 meters max.
  • Reviews+
  • Powercom KIN-2200APRM, 3U Rackmount 6 Outlet 2200VA/1320W

    Note: This product has been discontinued.

    AC INPUT

    • AC Input Capacity on Battery : 2200VA
    • AC Input Voltage (+/-) 25% at line input
    • AC Input Frequency : 50 or 60 Hz+/-10% (auto sensing)

    AC OUTPUT

    • AC Output Voltage Simulated sine ware at 115V +/-5%
    • AC Output Frequency : 50 or 60 Hz +/- 0.5%
    • AC Output Voltage Regulation AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal. AVR decrease output voltage 13% below input
    • voltage if +9% to +25% of nominal
    • AC Output Transfer : 2/4 milliseconds, including detection time

    PROTECTION

    • Protection Spike : 320 Joules, 2ms
    • Protection EMI/RFI : 10dB at 0.15 MHz, 50 dB at 30 MHz
    • Protection Overload UPS automatic shutdown if overload exceeds 110% nominal at 60 sec and 130% at 3 sec
    • Protection Unit Fuse for overload & short circuit protection
    • Protection 10 BaseT Network (UTP, RJ-45) compatible jacks
    • Protection Short Protection UPS output cut off immediately or input fuse protection

    BATTERY

    • Battery Type : Sealed, Maintenance-free lead acid
    • Battery Typical 8 hours (to 90% of full capacity)
    • Battery Protection Automatic self-test & discharge protection, replace battery indicator

    BACKUP TIME

    • Battery Backup Time Full Load : 7 minutes
    • Battery Backup Time Half Load : 15 minutes

    PHYSICAL

    • Physical Weight : 28Kg (61.1lbs)
    • Physical Shipping Weight kgs 32.7Kg (72lbs)
    • Physical Dimension : 483x351x130mm (19x13.8x5.1")

    ALARM

    • Alarm Battery Backup : Slow beeping sound (about 0.47 Hz)
    • Alarm Battery Low : Rapid beeping sound (about 1.82Hz)
    • Alarm Overload : Continue beeping sound

    INTERFACE

    • Interface RS-232 : RS-232C Bi-directional communication port

    ENVIRONMENT

    • Environment Ambient : 3,500 meters max. elevation, 0-95% humidity non-condensing, 0-40 deg c
    • Environment Audible : <40dBA (1 meter from surface) Environment Storage Condition : 15,000 meters max.
Open Google Reviews for our website ×